Sun Ray Absorber Plates
are a major part of our business and are also the most important component
of a solar collector for use in solar heating systems.
The absorbers are available to solar professionals and others for
new applications or as a replacement for solar collectors that have
suffered from loss in efficiency, freeze damage, clog, and leakage
or just as a replacement for an older model of any size-glazed collector.
The absorbers are also offered for glazed (glass covered) or unglazed
solar pool heating systems as an alternative choice to a plastic pool
heating panel (See a better
choice)
Some tips and benefits for a replacement absorber plate
With a replacement plate you end up with a solar collector that is
as good as new for the fraction of the cost of a new collector.
Sun Ray Absorbers are made to size to fit any collector
box. (See absorber measurements order form)
Sun Ray Absorbers can be replaced right on the roof
without disturbing the solar collector's current mountings. (See
absorber installation)
Sun Ray Absorbers are lightweight and therefore easily
lifted on to the roof.
Your damaged absorbers have a decent salvage value at your nearest
recycling center.

|

Features:
Sun Ray Absorbers are made of a plurality of our
unique roll formed fin-tubes; a design that makes our absorber plates
unique. (See fin-tubes)
Sun Ray Absorbers are available in all copper (copper
absorbing fins with copper flow tubing) or copper aluminum (aluminum
absorbing fins with copper flow tubing).
The 4 ¼" wide fin-tubes are brazed to ¾", 1", 1 ¼" or 1 ½" copper
headers.
The copper aluminum absorber's material is coated by professional
metal finishers. The metal is etched, washed, base coated chrome,
painted with durable-modified black solar absorbing polyester and
oven baked for efficiency, durability and a superior look.
The absorber plates weight is 1 lb. per sq./ft. for an all copper
plate or .60 lb. per sq./ft for copper aluminum plates.
The absorbers are able to withstand a stagnation temperature of 300°
F. and each absorber is pressure tested at 160 P.S.I.
Normal working pressure is up to 80 P.S.I.
Recommended flow rate for water heating systems: 0.05 +/- 0.01 GPM/SQ/FT.
Sample flow rate (3' x 8'absorber = 1.0 GPM) (4'x 10'absorber = 2.0
GPM)
Recommended flow rate for pool heating panels: 0.07 +/- 0.01 GPM/SQ/FT.
Sample flow rate (10- 4'x 10' pool panels = 28.0 GPM)

|